Refrigeration & Air-Conditioning True/False Quiz-1 - GateHelps

Latest

This blog is helpful for gate online preparation. We provide gate study materials, short notes, video lectures which covers entire syllabus of gate.

Thursday, July 6, 2017

Refrigeration & Air-Conditioning True/False Quiz-1

01. The temperature rise, between the condenser outlet and expansion valve in ammonia vapour
compression system, should be as low as possible.
A) Yes
B) No


02. During sub-cooling, sensible heat from a liquid refrigerant is removed.
A) Yes
B) No


03. The expression [Pv (Pb - Pd)/ Pd (Pb - Pv)] is used for calculating relative humidity.
A) Yes
B) No


04. The final relative humidity of the air during cooling and dehumidification is generally
__________ than that of entering air.
A) Lower
B) Higher


05. In a pressure enthalpy chart, the space between the saturated liquid line and saturated vapour
line represents sub-cooled liquid region.
A) True
B) False


06. R-11 has the highest critical point temperature.
A) Correct
B) Incorrect


07. The mass of water vapour present in 1 kg of dry air, is called humidity ratio.
A) True
B) False


08. When the discharge pressure is too high in a refrigeration system, high pressure control is
installed to stop the compressor.
A) Correct
B) Incorrect


09. In absorption vapour systems, the refrigerant widely used is R-12.
A) Correct
B) Incorrect


10. A Bell Coleman refrigerator working on dense air system as compared to open air system, for
the same range of temperature, results in higher coefficient of performance.
A) Agree
B) Disagree


11. Dew point temperature is the temperature of air recorded by a thermometer, when the
moisture present in it begins to condense.
A) Correct
B) Incorrect


12. If the condenser temperature is kept constant, the coefficient of performance of a
refrigeration cycle increases with the increase in evaporator temperature.
A) Yes
B) No


13. The relative humidity ________ as air gets drier.
A) Increases
B) Decreases


14. The coefficient of performance (C.O.P.) is the reciprocal of the efficiency of a heat engine.
A) True
B) False


15. The coefficient of performance of vapour compression refrigeration system is quite ________
as compared to air refrigeration system.
A) Low
B) High


16. During sensible cooling of air, the relative humidity increases.
A) Yes
B) No


17. The heating of air, without any change in its specific humidity, is known as sensible heating.
A) True
B) False


18. The absolute humidity is the mass of water vapour present in 1 m3 of dry air.
A) Agree
B) Disagree


19. A condenser is used in the _________ pressure side of a refrigerating system.
A) Low
B) High


20. R-12 has the ________ freezing point.
A) Lowest
B) Highest






Answers: Refrigeration & Air-Conditioning-I
01. Answer: Option A 
02. Answer: Option A 
03. Answer: Option B 
04. Answer: Option B
05. Answer: Option B 
06. Answer: Option A 
07. Answer: Option A 
08. Answer: Option A
09. Answer: Option B 
10. Answer: Option A 
11. Answer: Option A 
12. Answer: Option A
13. Answer: Option A 
14. Answer: Option A 
15. Answer: Option B 
16. Answer: Option A
17. Answer: Option A 
18. Answer: Option A 
19. Answer: Option B 
20. Answer: Option A